WELDMARK 225
OPERATOR’S MANUAL
For Machines with Code Number 10992
IM806
September, 2005
Safety Depends on You
Lincoln arc welding and cutting
equipment is designed and built
with safety in mind. However, your
overall safety can be increased by
proper installation ... and thought-
ful operation on your part. DO
NOT INSTALL, OPERATE OR
REPAIR THIS EQUIPMENT
WITHOUT READING THIS
MANUAL AND THE SAFETY
PRECAUTIONS CONTAINED
THROUGHOUT. And, most
importantly, think before you act
and be careful.
R
• Manufactured by Lincoln Electric Company •
Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com
Copyright © 2005 Lincoln Global Inc.
RETURN TO MAIN MENU
Seitenansicht 0
1 2 3 4 5 6 ... 36 37

Inhaltsverzeichnis

Seite 1 - WELDMARK 225

WELDMARK 225OPERATOR’S MANUALFor Machines with Code Number 10992IM806September, 2005Safety Depends on YouLincoln arc welding and cuttingequipment is

Seite 2 - MAGNETIC FIELDS

A-3INSTALLATION WELDMARK 225A-3INSTALLATION INSTRUCTIONSSafety PrecautionsMACHINE GROUNDINGBecause this portable engine driven welder creates itso

Seite 3 - FUMES AND GASES

A-4INSTALLATION WELDMARK 225A-4TOWINGThe recommended trailer for use with this equipment for road,in-plant and yard towing by a vehicle(1)is Lincol

Seite 4

• Damage to the fuel tank may causefire or explosion. Do not drill holesin the WELDMARK 225 base or weldto the WELDMARK 225 base.A-5INSTALLATION

Seite 5 - REDRESSEUR

A-6INSTALLATION WELDMARK 225A-6CONNECTION OF THE LN-7 TO THE WELDMARK225• Shut the welder off.• Connect the LN-7 and the K240 contactor kit perinst

Seite 6 - Thank You

A-7INSTALLATION WELDMARK 225A-7115 V DUPLEX RECEPTACLESThe 115V auxiliary power receptacles should only beused with three wire grounded type plugs

Seite 7 - TABLE OF CONTENTS

A-8INSTALLATION WELDMARK 225A-8TABLE lllELECTRICAL DEVICE USE WITH THE WELDMARK 225Type Common Electrical Devices Possible ConcernsResistive Heater

Seite 8

A-9INSTALLATION WELDMARK 225A-9STANDBY POWER CONNECTIONSThe Weldmark 225 is suitable for temporary, standby,or emergency power using the engine man

Seite 9 - OUTPUT VOLTS DC (RMS)

A-10INSTALLATION WELDMARK 225A-10Connection of Weldmark 225 to premises wiringmust be done by a licensed electrician and mustcomply with the Nation

Seite 10 - INSTALLATION

B-1OPERATIONWELDMARK 225B-1GENERAL DESCRIPTIONThe Weldmark 225 is a twin-cylinder, gasoline driven,multiprocess arc welder and AC power generator. It

Seite 11

B-2OPERATIONB-2Welder Controls - Function and OperationENGINE “ON-OFF” SwitchWhen placed in the “ON” position, this switchenergizes the engine ignitio

Seite 12

FOR ENGINEpowered equipment.1.a. Turn the engine off before troubleshooting and maintenancework unless the maintenance work requires it to be running.

Seite 13

B-3OPERATIONB-3Starting/Shutdown InstructionsStarting the EngineBe sure all Pre-Operation Maintenance has been per-formed. Also, read the Engine Owne

Seite 14

B-4OPERATIONB-4WELDING PROCESSDUTY CYCLEDuty Cycle is the the percentage of time the load isbeing applied in a 10 minute period. For example, a60% dut

Seite 15

B-5OPERATIONB-5WELDMARK 225SUMMARY OF WELDING PROCESSESCONTROL ELECTRODECABLE IDLE WHEN NOT

Seite 16

C-1ACCESSORIESC-1WELDMARK 225OPTIONAL EQUIPMENT (Field Installed)K957-1 HEAVY DUTY, TWO WHEEL TRAILER FORSMALL WELDERS - For road, off-road and in-p

Seite 17

C-2ACCESSORIESC-2WELDMARK 225RECOMMENDED EQUIPMENTSTICKK704 Accessory Kit which includes:• Electrode Holder & Cable• Work Clamp & Cable• H

Seite 18 - OPERATION

D-1MAINTENANCED-1WELDMARK 225SAFETY PRECAUTIONSHave qualified personnel do the maintenancework. Turn the engine off before working insidethe machine.

Seite 19

D-2MAINTENANCED-2Use 4-stroke motor oil that meets or exceeds therequirements for API service classification SG or SH.Always check the API SERVICE lab

Seite 20

D-3MAINTENANCED-3ENGINE ADJUSTMENTSOVERSPEED IS HAZARDOUSThe maximum allowable high idle speed for thismachine is 3750 RPM, no load. Do NOT tamperwit

Seite 21

D-4MAINTENANCED-4GFCI RECEPTACLE TESTING AND RESET-TING PROCEDUREThe GFCI receptacle should be properly tested atleast once every month or whenever it

Seite 22

E-1TROUBLESHOOTINGE-1WELDMARK 225If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, conta

Seite 23 - ACCESSORIES

iiSAFETYiiARC RAYS can burn.4.a. Use a shield with the proper filter and coverplates to protect your eyes from sparks andthe rays of the arc when weld

Seite 24

E-2TROUBLESHOOTINGE-2WELDMARK 225Observe all Safety Guidelines detailed throughout this manualIf for any reason you do not understand the test proced

Seite 25 - MAINTENANCE

E-3TROUBLESHOOTINGE-3WELDMARK 225Observe all Safety Guidelines detailed throughout this manualIf for any reason you do not understand the test proced

Seite 26

WELDMARK 225F-1DIAGRAMSWELDMARK 225 WIRING DIAGRAM CODE 10992F-1NOTE: This diagram is for reference only. It may not be accurate for all machines

Seite 27

F-2DIAGRAMSF-2WELDMARK 225CONNECTION OF WELDMARK 225 TO LN-7 & K240 CONTACTOR KITWARNING: Turn the power off when making connections.N.A. Use pow

Seite 28

F-3DIAGRAMSF-3WELDMARK 225LOF SHAFT9.2921.219.312.7517.0026.5919.1130.289.099.09UNDERCARRIAGE MOUNTING HOLES42.25CENTER OF GRAVITY WITH OIL INENGINE

Seite 29 - TROUBLESHOOTING

WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicREAD AND UNDERSTAND THE MANUFACTURER’S INSTRUC

Seite 30

WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicLEIA E COMPREENDA AS INSTRUÇÕES DO FABRICANTE

Seite 31

•Manufactured by Lincoln Electric Company •Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.

Seite 32 - DIAGRAMS

FOR ELECTRICALLYpowered equipment.8.a. Turn off input power using the disconnectswitch at the fuse box before working onthe equipment.8.b. Install equ

Seite 33

ivSAFETYivPRÉCAUTIONS DE SÛRETÉPour votre propre protection lire et observer toutes les instructionset les précautions de sûreté specifiques qui parra

Seite 34

Thank Youfor selecting a QUALITY product We want you to take pridein operating this product ••• as much pride as we have inbringing this product to yo

Seite 35

viTABLE OF CONTENTSPageInstallation...

Seite 36

A-1INSTALLATION WELDMARK 225A-1* Based on a 10 min. period.TECHNICAL SPECIFICATIONS - WELDMARK 225 (WEM 2239-2 CSA MEETS CANADIAN STD) INPUT - GA

Seite 37

A-2INSTALLATION WELDMARK 225A-2AC STICK / TIG (CC) OUTPUTA 225 OUTPUT RANGEB 50 OUTPUT RANGEABOUTPUT AMPSOUTPUT VOLTS AC (RMS)050 100 150 20025