F-13
TROUBLESHOOTING & REPAIR
F-13
7. If the correct test voltages are pre-
sent the auxiliary transformer is good.
8. If any of the voltages are missing or
very low, with the proper primary
voltage applied, the auxiliary trans-
former may be faulty. Replace.
9. If the auxiliary transformer tests good
but does not function when connect-
ed to the V250-S check the harness
wiring to the auxiliary transformer.
See wiring diagram.
AUXILIARY TRANSFORMER TEST (continued)
INVERTEC V250-S
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TEST POINT TEST POINT EXPECTED VOLTAGE
H1 (1J7) H2 (4J7) 200 - 208VAC
H1 (1J7) H4 (3J7) 380 - 415VAC
H1 (1J7) H5 (6J7) 440 - 460VAC
RED LEAD (1J1) RED LEAD (3J1) 18VAC (SECONDARY)
On Control Board On Control Board
TABLE F.1 Auxiliary Transformer Test Points