Lincoln-electric SP-135 PLUS IM725 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Werkzeug Lincoln-electric SP-135 PLUS IM725 herunter. Lincoln Electric SP-135 PLUS IM725 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 48
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
SP-135 PLUS
OPERATOR’S MANUAL
IM725
December, 2001
Safety Depends on You
Lincoln arc welding and cutting
equipment is designed and built
with safety in mind. However, your
overall safety can be increased by
proper installation ... and thought-
ful operation on your part.
DO
NOT INSTALL, OPERATE OR
REPAIR THIS EQUIPMENT
WITHOUT READING THIS
MANUAL AND THE SAFETY
PRECAUTIONS CONTAINED
THROUGHOUT.
And, most
importantly, think before you act
and be careful.
For use with machine Code Numbers : 10868
• Sales and Service through Subsidiaries and Distributors Worldwide •
Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com
• World's Leader in Welding and Cutting Products •
Date of Purchase:
Serial Number:
Code Number:
Model:
Where Purchased:
Copyright © 2001 Lincoln Global Inc.
RETURN TO MAIN MENU
Seitenansicht 0
1 2 3 4 5 6 ... 47 48

Inhaltsverzeichnis

Seite 1 - SP-135 PLUS

SP-135 PLUSOPERATOR’S MANUALIM725December, 2001Safety Depends on YouLincoln arc welding and cuttingequipment is designed and builtwith safety in mind.

Seite 2 - MAGNETIC FIELDS

A-3A-3INSTALLATIONSP-135 PLUSSELECT SUITABLE LOCATIONLocate the welder in a dry location where there is freecirculation of clean air into the louvers

Seite 3 - FUMES AND GASES

A-4SP-135 PLUSA-4INSTALLATION3. Route the cable under and around the back of theWire Feed Gearbox (6).4. For GMAW Only: Refer to Figure A.2. As deliv-

Seite 4

A-5A-5INSTALLATIONSP-135 PLUS3. Attach the flow regulator to the cylinder valve andtighten the union nut securely with a wrench. Theflow regulator for

Seite 5 - REDRESSEUR

A-6 A-6INSTALLATIONSP-135 PLUSCODE REQUIREMENTS FOR INPUTCONNECTIONSThis welding machine must be connected topower source in accordance with applicabl

Seite 6 - Thank You

SP-135 PLUSB-1B-1OPERATIONRead entire Operation section beforeoperating the SP-135 PLUS.ELECTRIC SHOCK can kill.• Do not touch electrically liveparts

Seite 7 - TABLE OF CONTENTS

B-2SP-135 PLUSB-2OPERATIONGENERAL DESCRIPTIONThe SP-135 PLUS is a complete semiautomatic con-stant voltage DC arc welding machine. Included is asolid

Seite 8

SP-135 PLUSB-3B-3OPERATIONFIGURE B.1a4. Circuit Breaker – Protects machine from damage ifmaximum output is exceeded. Button will extendout when trippe

Seite 9

B-4B-4OPERATIONFIGURE B.3Friction Brake AdjustmentWith wire spool installed on the spindle shaft and thewing nut loose, turn the spool by hand while s

Seite 10 - INSTALLATION

SP-135 PLUSB-5B-5OPERATIONShielding GasWhen using the GMAW process, a cylinder of shield-ing gas, must be obtained. Refer to the ACCES-SORIES section

Seite 11

B-6SP-135 PLUSB-6OPERATION9. To stop welding, release the gun trigger and thenpull the gun away from the work after the arc goesout.10. When no more w

Seite 12

SP-135 PLUSFOR ENGINEpowered equipment.1.a. Turn the engine off before troubleshooting and maintenancework unless the maintenance work requires it to

Seite 13

SP-135 PLUSB-7B-7OPERATIONOVERLOAD PROTECTIONOutput OverloadThe SP-135 PLUS is equipped with a circuit breakerwhich protects the machine from potentia

Seite 14 - OPERATION

B-8SP-135 PLUSB-8LEARNING TO WELDLEARNING TO WELDNo one can learn to weld simply by reading about it.Skill comes only with practice. The following pag

Seite 15

SP-135 PLUSB-9B-9LEARNING TO WELDThe “arc stream” is seen in the middle of the picture.This is the electric arc created by the electric currentflowing

Seite 16

B-10SP-135 PLUSB-10LEARNING TO WELDFor GMAW (MIG) Process1. Is most of my welding performed on 16 gauge andlighter materials?2. Can I afford the extra

Seite 17 - To wire drive

SP-135 PLUSB-11B-11LEARNING TO WELDFIGURE B.12PenetrationUnless a weld penetrates close to 100% of the metalthickness, a butt weld will be weaker than

Seite 18 - GUN CABLE

B-12SP-135 PLUSB-12LEARNING TO WELDFIGURE B.16Vertical-down WeldingRefer to Figure B.17 Vertical-down welds are appliedat a fast pace. These welds are

Seite 19

SP-135 PLUSB-13B-13LEARNING TO WELDARC RAYS can burn eyes and skin.When using an open arc process, itIs necessary to use correct eye,head and body pro

Seite 20

B-14SP-135 PLUSB-14LEARNING TO WELDMild Steel 16 gauge or 1/16 inch(1.6 mm)Electrode 0.035" (0.9 mm)NR-211-MPInnershield WireVoltage Setting “V”

Seite 21 - LEARNING TO WELD

SP-135 PLUSB-15B-15LEARNING TO WELDMACHINE SET UP FOR THE GMAW (MIG)PROCESS1. See PROCESS GUIDELINES in the OPERATIONsection for selection of welding

Seite 22

Helpful Hints1. For general welding, it is not necessary to weavethe arc, neither forward or backward nor sideways.Weld along at a steady pace. You wi

Seite 23

SP-135 PLUSiiSAFETYiiARC RAYS can burn.4.a. Use a shield with the proper filter and coverplates to protect your eyes from sparks andthe rays of the ar

Seite 24

SP-135 PLUSB-17B-17LEARNING TO WELD4. After you strike the arc, practice the correct electri-cal stickout. Learn to distinguish it by its sound.5. Whe

Seite 25

SP-135 PLUSB-18B-18LEARNING TO WELDProper Gun HandlingMost feeding problems are caused by improper han-dling of the gun cable or electrodes.1. Do not

Seite 26

B-19B-19APPLICATION CHARTSP-135 PLUS

Seite 27

C-1C-1SP-135 PLUSACCESSORIES4. KP666-035C Knurled Drive Roll (optional) —Reversible Drive Roll with double knurled groovesfor .035 (0.9 mm) cored elec

Seite 28

C-2C-2SP-135 PLUSACCESSORIESINNERSHIELD (FCAW)CONVERSIONSeveral changes are needed to convert the unit foroperation with the Innershield (FCAW) proces

Seite 29

SP-135 PLUSMAINTENANCESAFETY PRECAUTIONSELECTRIC SHOCK can kill.• Disconnect input power byremoving plug from receptaclebefore working inside SP-135PL

Seite 30

D-2SP-135 PLUSD-2MAINTENANCEGUN AND CABLE MAINTENANCEFOR MAGNUM™ 100L GUNGun Cable CleaningClean cable liner after using approximately 300 lbs(136 kg)

Seite 31

D-3SP-135 PLUSD-3MAINTENANCECOMPONENT REPLACEMENT PROCEDURESCHANGING THE CONTACT TIP1. Unplug or turn power switch to Off “O” position.2. Refer to Fig

Seite 32 - APPLICATION CHART

D-4GUN HANDLE PARTSThe gun handle consists of two halves that are heldtogether with a collar on each end. To open up thehandle, turn the collars appro

Seite 33 - ACCESSORIES

SP-135 PLUSIf machine case sides and top are removed, the case front must be supported. Failureto do this could result in mechanical or electrical dam

Seite 34

SP-135 PLUSFOR ELECTRICALLYpowered equipment.8.a. Turn off input power using the disconnectswitch at the fuse box before working onthe equipment.8.b.

Seite 35 - MAINTENANCE

E-2SP-135 PLUSE-2TROUBLESHOOTINGObserve Safety Guidelinesdetailed in the beginning of this manual.TROUBLESHOOTING GUIDEPROBLEMS(SYMPTOMS)Major physica

Seite 36

SP-135 PLUSE-3E-3TROUBLESHOOTINGObserve Safety Guidelinesdetailed in the beginning of this manual.TROUBLESHOOTING GUIDEPROBLEMS(SYMPTOMS)No wire feed

Seite 37

E-4SP-135 PLUSE-4TROUBLESHOOTINGObserve Safety Guidelinesdetailed in the beginning of this manual.TROUBLESHOOTING GUIDEPROBLEMS(SYMPTOMS)Arc is unstab

Seite 38

F-1SP-135 PLUSF-1WIRING DIAGRAMSM19922L1L23132531TO GROUNDPER NATIONALELECTRICAL CODES1SWITCH202201D1D3D2D4204204204203203203C159,000 f40V203204-+OUT

Seite 40

Now Available...12th EditionThe Procedure Handbook of Arc WeldingWith over 500,000 copies of previous editions publishedsince 1933, the Procedure Hand

Seite 41

WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicREAD AND UNDERSTAND THE MANUFACTURER’S INSTRUC

Seite 42

WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicLEIA E COMPREENDA AS INSTRU ES DO FABRICANTE P

Seite 43 - SP-135PLUS WIRING DIAGRAM

• Sales and Service through Subsidiaries and Distributors Worldwide •Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB

Seite 44

SP-135 PLUSivSAFETYivPRÉCAUTIONS DE SÛRETÉPour votre propre protection lire et observer toutes les instructionset les précautions de sûreté specifique

Seite 45 - Lincoln Welding School

SP-135 PLUSThank Youfor selecting a QUALITY product by Lincoln Electric. We want youto take pride in operating this Lincoln Electric Company product••

Seite 46

viviSP-135 PLUSTABLE OF CONTENTSPageInstallation ...

Seite 47

A-1A-1INSTALLATIONSP-135 PLUSFuse orOutput Mode Input Voltage Breaker Size Input Amps Extension CordThree Conductor#14 AWGRATED 115V/60Hz 20 Amp 20 (2

Seite 48

A-2 A-2INSTALLATIONSP-135 PLUSRead entire installation section before startinginstallation.SAFETY PRECAUTIONSIDENTIFY AND LOCATE COMPONENTSIf you have