A-3
INSTALLATION
INVERTEC V200-T
A-3
a) A metal underground water pipe in direct con-
tact with the earth for ten feet or more.
b) A 3/4” (19mm) galvanized pipe or a 5/8” (16mm)
solid galvanized iron, steel or copper rod driven
at least eight feet into the ground.
The ground should be securely made and the ground-
ing cable should be as short as possible using cable
of the same size as the work cable, or larger.
Grounding to the building frame electrical conduit or a
long pipe system can result in re-radiation, effectively
making these members radiating antennas.
6. Keep cover and all screws securely in place.
7. Electrical conductors within 50 ft (15.2m) of the
welder should be enclosed in grounded rigid metal-
lic conduit or equivalent shielding, wherever possi-
ble. Flexible metallic conduit is generally not suit-
able.
8. When the welder is enclosed in a metal building,
the metal building should be connected to several
good earth driven electrical grounds (as in 5 (b)
above) around the periphery of the building.
Failure to observe these recommended installation
procedures can cause radio or TV and electronic
equipment interference problems and result in unsat-
isfactory welding performance resulting from lost high
frequency power.
INPUT CONNECTIONS
Be sure the voltage, phase, and frequency of the input
power is as specified on the rating plate, located on
the rear of the machine.
Supply line entry provision is in the case rear panel.
A power cord is provided and wired into the machine.
Follow the power cord connection instructions.
Incorrect connection may result in equipment damage.
The Invertec V200-T is internally connected for a 460
volt input. The input switch has a lock pin which restricts
movement for 460 selection only. See figure A.1.
To connect the V200-T for 230 volt input, the following
input reconnect needs to be completed.
1. Disconnect the machine from the input supply.
2. Remove the wraparound by removing the shoul-
der strap brackets and wraparound screws.
3. Provide access to the line switch by bending the
insulation back.
4. When the insulation is bent back, two sleeved
leads will become visible.
5. Remove the sleeving from both leads.
6. Connect the large lead to push-on terminal
labeled “3” on the adjacent PC board.
7. Connect the small lead to terminal 15 of the line
switch.
8. Reposition insulation to cover line switch.
9. Re-install wraparound.
10. Move the lock pin to allow switch movement for
230 V selection only.
Connect the green w/ yellow strip lead to ground per
U.S. National Electrical Code. Connect the black and
white leads to power.
Use reverse procedure to reconnect for 460V. Do not
connect 460V when the switch is configured for 230V
or damage will
result.
Figure A.1
INPUT FUSE AND SUPPLY WIRE
Refer to the
Technical Specifications
pages at the
beginning of this chapter for the proper fuse sizes and
supply cable sizes.
Fuse the input circuit with recommended super lag
fuses or delay type circuit breakers.
Install the proper fuse in the fuse holder in the main
disconnect panel.
OUTPUT CONNECTIONS
Figure A.2
230460
0
Power ON-OFF/Voltage Selector Switch - Located on top right of rear panel
Lock pin mounting hole
Lock pin - in this position allows only
230 V input selection Move to opposite
side for 460 V operation.
TIG TORCH/GAS OUTLET
RECEPTACLE
WORK CABLE RECEPTACLE
Seitenansicht 9