Lincoln Electric INVERTEC V200-T Bedienungsanleitung Seite 18

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 32
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 17
B-6
OPERATION
B-6
EXPLANATION OF 2 STEP AND 4
STEP MODES
(See figure B.2 and the explanations that follow)
2 STEP
2 Step mode can be used with either an arc start
switch or a hand or foot amptrol. The welding cycle
begins when the torch switch is held closed and ends
when the switch is released.
4 STEP
4 Step mode should only be used with an arc start
switch. The welding cycle begins when the torch
switch is pressed and then released. The cycle is
ended by a further press and release of the switch.
The pre-gas flow is followed by an increase in the
welding current from the level set by the Start/Crater
Current Potentiometer, to the value on the display
set with the Welding Current Potentiometer. The
rate of increase is determined by the setting of the
Slope Up Time Potentiometer.
The slope out phase begins with the release of the
torch switch in the 2 STEP mode or with a second
press of the switch in the 4 STEP mode.
During this phase, the welding current falls to the
crater current set on the Start/Crater Current
Potentiometer. The speed at which the welding cur-
rent decreases is determined by the setting of the
Slope Down Time Potentiometer.
The power source comes equipped with a restart
capability. Any change required in the restart timing
can only be made by an authorized service center.
(See Figure B.2 - 4 Step Mode).
In the TIG-SPOT mode the UP/ DOWN-SLOPE con-
trols and the PULSER function are disabled.
The welding cycle takes an "ON-OFF" type shape with
the welding current jumping very rapidly from 0 to the
nominal value.
PULSER FUNCTION
Pulsed welding is selected by using the TIG Process
Switch. In this mode the output is modulated to pro-
duce a series of current pulses. By this means pre-
cise control of heat input and penetration can be
achieved on critical applications. The pulse frequency,
duration and amplitude may be adjusted by means of
the respective potentiometers.
INVERTEC V200-T
2 STEP MODE
TORCH
SWITCH
WELDING
CURRENT
TORCH
SWITCH
WELDING
CURRENT
4 STEP MODE
TORCH
SWITCH
WELDING
CURRENT
TORCH
SWITCH
WELDING
CURRENT
WITHOUT RESTART
WITH RESTART (As shipped
no jumper)
CRATER CURRENT
FIGURE B.2 2 Step and 4 Step Modes
Seitenansicht 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 31 32

Kommentare zu diesen Handbüchern

Keine Kommentare